What can you do with Thermokon and Niko Home Control?
Get a notification when water leakage is detected
If you connect your water leakage sensor to Niko Home Control, you can get a notification when water is detected. You will be informed via the Niko Home app on a tablet or smartphone and/or the Touchscreen.
We recommend the following options to make even better use of this connection:
Close the water valve automatically when water leakage is detected, see https://guide.niko.eu/en/smnhc2/lv/creating-a-condition.
What do you need?
Niko requirements
Your Niko Home Control installation meets the following requirements:
-
It has a wireless smart hub or a connected controller II.
-
It is configured with the most recent programming software.
Depending on the basic modules of your Niko Home Control installation, you need to install the following additional products:
|
|
Required additional products |
Reference numbers |
|---|---|---|
|
Connected controller |
Digital potential-free sensor module with one free input per signal that you want to use in Niko Home Control If the output contact on your third-party device is not potential-free, you need an additional potential-free contact module (e.g. Finder 22.32.0.230.1xx0 for 230 V connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections) |
|
|
Connected controller with a wireless bridge |
Connected (double) switch with one free input (E) per signal that you want to use in Niko Home Control If the output contact on your third-party device is not 230 V, you need an additional 230 V contact module (e.g. Finder 22.32.0.230.1xx0 for potential-free connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections) The connected (double) switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950) |
|
|
Wireless smart hub |
Connected (double) switch with one free input (E) per signal that you want to use in Niko Home Control If the output contact on your third-party device is not 230 V, you need an additional 230 V contact module (e.g. Finder 22.32.0.230.1xx0 for potential-free connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections) The connected (double) switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950) |
Thermokon requirements
Your system meets the following requirements:
-
Your water leakage sensor has a potential free or 12/24 V DC or 230 V AC output contact.
-
It is compatible with the Niko module (see Niko requirements).
Your system is one of the following Thermokon products*:
|
|
Potential-free contact |
|---|---|
|
Water leakage detectors |
|
*Consult the website of the supplier for detailed specifications and the latest products.
Wiring diagrams
Connecting the sensor module
Via potential-free output contact
Connect contact 1 on the Niko sensor module to the output on the third-party system, as shown in the wiring diagram.
|
|
Potential-free output contact |
|---|---|
|
Thermokon water leakage detector |
Contact 4-5 |
Connecting the connected switch
Via potential-free output contact
If the contacts of your alarm system are not 230 V, you additionally need an appropriate potential-free contact module.
Connect contact 1 on the Niko connected switch to the output on the third-party system, as shown in the wiring diagram.
*230 V to potential-free contact module (e.g. Finder 22.32.0.230.1xx0)
|
|
Potential-free output contact |
|---|---|
|
Thermokon water leakage detector |